Suche

Wo soll gesucht werden?
Erweiterte Literatursuche

Ariadne Pfad:

Inhalt

Literaturnachweis - Detailanzeige

 
Autor/inn/enNe´el, Bastien; Crespo, Gasto´n A.; Perret, Didier; Cherubini, Thomas; Bakker, Eric
TitelCamping Burner-Based Flame Emission Spectrometer for Classroom Demonstrations
QuelleIn: Journal of Chemical Education, 91 (2014) 10, S.1655 (6 Seiten)Infoseite zur Zeitschrift
PDF als Volltext Verfügbarkeit 
Spracheenglisch
Dokumenttypgedruckt; online; Zeitschriftenaufsatz
ISSN0021-9584
DOI10.1021/ed4008149
SchlagwörterHigh School Students; Secondary School Science; Spectroscopy; Science Instruction; Chemistry; Laboratory Equipment; Laboratory Experiments; Water; Comparative Analysis
AbstractA flame emission spectrometer was built in-house for the purpose of introducing this analytical technique to students at the high school level. The aqueous sample is sprayed through a homemade nebulizer into the air inlet of a consumer-grade propane camping burner. The resulting flame is analyzed by a commercial array spectrometer for the visible spectrum in the range of 350-1000 nm. The cost of the instrument is mainly given by that of the spectrometer and computer/projector. The obtained emission spectrum is characteristic of each individual atom, such as sodium (589 nm) and potassium (766 nm), or molecule, such as calcium hydroxide (554 and 622 nm). The readout signal (either peak height or peak area) is shown to be proportional to the sample concentration. Both qualitative and quantitative analyses may be performed with this robust and low-cost device. Samples can be rapidly changed, giving a 95% response time of under 3 s. The analytical figures of merit were characterized for calcium, potassium, and sodium in different water samples, and the resulting precision (standard deviation) for a 1 s acquisition time was typically on the order of 2%. Observed calcium levels were lower than expected because of the presence of refractory compounds, such as calcium phosphate or sulfate, that are difficult to fully atomize with the simple flame used here. Lanthanum(III) chloride was successfully used to increase the calcium response. The lower limit of detection for sodium was approximately 3 ppb and comparable to that of conventional commercial emission spectrometers. (As Provided).
AnmerkungenDivision of Chemical Education, Inc and ACS Publications Division of the American Chemical Society. 1155 Sixteenth Street NW, Washington, DC 20036. Tel: 800-227-5558; Tel: 202-872-4600; e-mail: eic@jce.acs.org; Web site: http://pubs.acs.org/jchemeduc
Erfasst vonERIC (Education Resources Information Center), Washington, DC
Update2017/4/10
Literaturbeschaffung und Bestandsnachweise in Bibliotheken prüfen
 

Standortunabhängige Dienste
Bibliotheken, die die Zeitschrift "Journal of Chemical Education" besitzen:
Link zur Zeitschriftendatenbank (ZDB)

Artikellieferdienst der deutschen Bibliotheken (subito):
Übernahme der Daten in das subito-Bestellformular

Tipps zum Auffinden elektronischer Volltexte im Video-Tutorial

Trefferlisten Einstellungen

Permalink als QR-Code

Permalink als QR-Code

Inhalt auf sozialen Plattformen teilen (nur vorhanden, wenn Javascript eingeschaltet ist)

Teile diese Seite: