Literaturnachweis - Detailanzeige
Autor/inn/en | Lins-Filho, Ozeas L.; Santos, Tony M.; Ritti-Dias, Raphael M.; Damasceno, Vinícius O.; Ferreira, Daniela K. S. |
---|---|
Titel | The Absolute and Relative Reliability of Psychophysiological Responses to Self-Selected Exercise Intensity in Elderly Women |
Quelle | In: Research Quarterly for Exercise and Sport, 90 (2019) 3, S.270-275 (6 Seiten)
PDF als Volltext |
Zusatzinformation | ORCID (Lins-Filho, Ozeas L.) ORCID (Santos, Tony M.) ORCID (Ritti-Dias, Raphael M.) ORCID (Damasceno, Vinícius O.) ORCID (Ferreira, Daniela K. S.) |
Sprache | englisch |
Dokumenttyp | gedruckt; online; Zeitschriftenaufsatz |
ISSN | 0270-1367 |
DOI | 10.1080/02701367.2019.1593922 |
Schlagwörter | Females; Older Adults; Psychophysiology; Exercise; Psychological Patterns; Reliability; Measurement; Correlation; Responses; Perception; Physical Activity Level |
Abstract | Background: Self-selected exercise intensity (SSEI) promotes higher affect (pleasure) during exercise, but its reliability is still unclear. Purpose: to evaluate the test-retest reliability and the minimum detectable change of the perceptive and physiological responses in two sessions of SSEI on treadmill in elderly women. Method: Twenty elderly women (ages 65.3 [plus-minus] 4.2 years) performed two 20-min laboratory-based treadmill aerobic exercise sessions with self-selected intensity. During the sessions, %VO[subscript 2max], %HR[subscript reserve], affect, and rating of perceived exertion (RPE) were recorded. Reliability was calculated using the intraclass correction coefficient (ICC) and Bland-Altman plots. The minimum detectable change (MDC) was also calculated. Results: ICC values were 0.98 for % VO[subscript 2max], 0.83 for % HR[subscript reserve], 0.85 for affect, and 0.80 for RPE. No differences were observed in mean values between sessions for all the variables. MDCs were lower than 0.7% for VO[subscript 2max], 11.7% for HR[subscript reserve], 0.7 for affect, and 0.8 for RPE. Bland-Altman plots showed a bias of 0.50% for HR[subscript reserve], 3.2% for VO[subscript 2max], 0.05 for affect, and -0.35 for RPE. Conclusion: Self-selected intensity during aerobic exercise performed on treadmill is reliable, which promotes adequate and lower MDC values on physiological and perceptual responses in elderly women. (As Provided). |
Anmerkungen | Routledge. Available from: Taylor & Francis, Ltd. 530 Walnut Street Suite 850, Philadelphia, PA 19106. Tel: 800-354-1420; Tel: 215-625-8900; Fax: 215-207-0050; Web site: http://www.tandf.co.uk/journals |
Erfasst von | ERIC (Education Resources Information Center), Washington, DC |
Update | 2020/1/01 |